DESCRIPTION
    Sentinel
    ®
    is James Walker’s
    general purpose sheet jointing. It
    comprises compressed aramid
    fibres with nitrile rubber (NBR)
    binder. An anti-stick finish to both
    surfaces is supplied as standard.
    PRIME FEATURES
    Replaces CAF for most
    industrial duties up to 400°C.
    Suitable for wide range of
    media.
    Offers outstanding performance
    for its class.
    SPECIFICATION
    Exceeds the property requirements of BS7531 Grade Y.
    WRAS approved for use with hot and cold potable water up to 85°C.
    PHYSICAL PROPERTIES
    (Typical values for 1.5mm thick material)
    Density, Mg/m
    3
    1.6
    Transverse tensile strength, MPa 8.0 (ASTM F152)
    Residual stress, MPa 25.0 (BS7531)
    Compressibility, % 13.0 (BS7531)
    Recovery, % 45.0 (ASTM F36J)
    Gas permeability, ml/min <1.0 (BS7531)
    Leachable chloride ion content, ppm <100
    FLUID IMMERSION PROPERTIES
    ASTM oil 3, % thickness increase, 5h @ 150°C 5.0 (BS7531)
    ASTM fuel B, % thickness increase, 5h @ RT 6.0 (ASTM F146)
    Water, % thickness increase, 5h @ 100°C 9.0 (BS7531)
    SERVICE CAPABILITY
    For applications falling into the green zone, the product may normally be
    used without consultation. In the amber zone we recommend that our
    technical services team be contacted for confirmation of suitability. If the
    pressure/temperature combination is in the red zone then we must be
    consulted before the product is used. Class lines refer to ASME B16.5.
    HOW SUPPLIED
    Precision cut gaskets to any shape, size and quantity. In sheets 2.0m x 1.5m,
    1.5m x 1.0m. Thicknesses: 0.5mm, 0.75mm, 1.0mm, 1.5mm, 2.0mm. Please
    note that 3.0mm is also available but is not recommended (see page 30 for
    advice on gasket use).
    SENTINEL
    ®
    100
    80
    60
    40
    20
    0
    100 200
    300
    TEMPERATURE ( C)
    PRESSURE (BAR)
    400
    CLASS 600
    CLASS 400
    CLASS 300
    CLASS 150
    SENTINEL, up to and including 2mm thickness: maximum working
    pressure against temperature guidelines.
    SERVICE CAPABILITY GRAPH